Clean Filter

CAUTION:

TS206
TS206-UN-15APR13

N100433
N100433-UN-09OCT12

A - Sump Valve

B - Cap

Prevent serious injury or death.

Check chemical or fertilizer MSDS for proper handling instructions.

Toxic chemicals can enter the body by breathing spray or contact with bare skin. Do not take a chance with your health and safety.

Clean the filter at the start of each day when tank is empty or dirt is detected in system.

  1. Clear area of bystanders.

  2. Close sump valve (A) if there is liquid in tank.

  3. Relieve pressure in liquid circuit.

  4. Remove cap (B) to access screen.

  5. Use clear water to clean screen.

  6. IMPORTANT: Do not over tighten canister and crack head.

    Install screen in canister and tighten by hand.

  7. Open sump valve if there is liquid in tank.

KB78086,0000D43-19-20130401