The Variable Rate Drive Data Screen is the single best source
to diagnose VRD problems. The following must occur for the VRD system
to operate.
-
A target population must be entered and turned "ON".
-
VRD hydraulics must be flowing continuously at highest flow
rate.
-
Planter must be unfolded and lowered to planting height.
-
Height sensor must be calibrated and "Planter Position" must
indicate "Down".
-
Planter must be moving forward at planting speed.
-
"Ground Speed" must indicate a ground speed.
-
"Wheel Sensor" must indicate "Active".
-
NOTE: If Target RPM displays CAL, operate machine in the field
a short distance with VRD active. This calibrates motors.
Select Menu >> Planter button >> Diagnostics softkey
>> Readings tab.
-
Select VRD Data from drop down box.
The status and activity for VRD components is shown.