Adjust Blower Speed
NOTE:

A62491-UN-29APR08
A - Flow Control Valve
B - Gear-Type Motor
Before blower speed adjustment, allow tractor hydraulic oil
to warm up to operating temperature. Cold oil causes slower blower
speeds.
Adjust speed at valve (A) if the tractor does not have an SCV
with variable flow rate. A gear-type motor (B) drives the blower shaft.
Blower must coast down gradually when the oil supply is shut
off at the tractor to avoid damage. A check valve permits oil to flow
in one direction.
|
|
AG,OUZXMAG,49-19-20160122
|
|