Track Sensor Setup
Set Track Sensor Source
-

A63046-UN-13AUG08
Setup Icon

A63026-UN-13AUG08
Next Page

A63065-UN-14AUG08
Sensor Type
A - Drop Down Menu
Select Menu button >> select Drill Application icon >> select Function Toggle until icon set 2 is displayed >> select Setup icon >> select Next Page icon.
-
NOTE: Only drill drive wheel and tractor radar require calibration.
Other sensor sources are determined automatically.
Select drop down menu (A) and set source of track sensor.
Calibrate Track Sensor
-

A63064-UN-14AUG08

A63046-UN-13AUG08
Setup Icon
A - Start and Stop
B - Input Box
Select Menu button >> select Drill Application icon >> select Function Toggle until icon set 2 is displayed >> select Setup icon.
-
Select start (A) and drive tractor 100 m (328 ft.).
-
When complete, stop tractor and select stop (A). Drive wheel
pulses are displayed in input box (B).
-
Select input box (B) to manually enter drive wheel pulses.
|
|
NS43404,0000099-19-20081017
|
|