Controller Functions

A63446-UN-14OCT08
Controller
The controller is on the drill. The controller forms the
link between the separate sensors, actuators, and monitor.
A monitor located in the cab displays data from the controller
and allows user input to the controller.
A microprocessor in the controller processes the user entered
data and the signals transmitted by the sensors. The processed information
is converted into:
A. CONTROL SIGNALS: Signals sent from
the controller to operate the actuators.
-
Automatic tramline operation.
-
Seed meter shutoff.
B. ALARM SIGNALS: Signals sent to
the controller from the sensors that indicate malfunctions in the
monitored system.
-
Low blower speed alarm.
-
Low hopper alarm.
-
Meter operation sensors.
C. DISPLAY SIGNALS: Signals sent from
the controller to the monitor that displays the following information.
-
Operational status.
-
Tramline pattern.
-
Area covered in current field.
-
Total area covered.
-
Area worked per hour.
-
Work speed.
-
Hours operated.
-
Actual blower speed.
-
Hopper content.
-
Obstruction in seed delivery system.
-
Meter status.
|
|
NS43404,00000A8-19-20151208
|
|