Tractor Hydraulic System Requirements
Hydraulically driven blower requires tractor to have large oil
reservoirs and increased oil cooling capacity. Load sensing or closed
center hydraulic systems with flow control, deliver the oil flow needed
for the blower motor to run at the selected RPMs without surging.
Tractors with open center hydraulic systems are not recommended.
|
Hydraulic System Requirements
|
|
Number of SCVs (min.)
|
3
|
|
Liters-per-Minute (Gallons-per-Minute)
|
|
Single-Rank Machine
|
49—57 L/m (13—15 gal/min)
|
|
Two-Rank Machine
|
68—76 L/m (18—20 gal/min)
|
IMPORTANT: In addition to these requirements, tractor MUST be
equipped with a low-pressure drain line connection for the hydraulic
motor case drain. To prevent hydraulic motor damage, sump
pressure MUST be less than 172 kPa (1.72 bar) (25 psi).
If your tractor is not properly equipped, see your John Deere dealer
for installation of a Low-Pressure Drain Line Kit.
Verify that tractor hydraulic system meets all requirements.
|
John Deere
is a trademark of Deere & Company
|
MH69740,000042A-19-20160222
|
|