Operation Guidelines
-
Use recommended size tractor. (See Specifications section).
-
Verify that tractor and machine have been properly prepared.
(See Prepare the Tractor and Prepare the Machine sections).
-
Verify that hydraulic hoses are correctly connected to tractor.
Verify that hydraulic motor case drain hose is connected to low pressure
(under 172 kPa [1.72 bar] [25 psi]) return port and not crimped.
-
Customize meter wheels to agree with product.
-
Properly set meters for product being used. Use clean seed for
best metering. Use of lid screens is recommended.
-
Allow tractor hydraulic oil to warm up thoroughly before seeding.
Cold oil causes slower blower speeds.
-
Check seed rates carefully. Perform rate check and adjust transmission
output speed accordingly.
-
Set blower at recommended speed. Excessive speed causes increased
wear on air system and damaged seed.
-
Always shut off blower motor by placing SCV in float position.
-
Run blower at recommended rpm for 10 minutes, with machine stationary,
any time machine has been standing for over an hour in high humidity
or after sitting overnight.
-
Empty remaining product from tank and clean product residue
from meter segment flutes after each day of operation. Clean more
frequently when product contains a high level of debris (rocks, twigs,
sticks, straw, and so on). Open tank lids and remove any obstructions
from meter inlet openings.
|
|
MH69740,000042E-19-20160314
|
|