Frequent shear pin failures.
| Meter cup fills venturi with seed during transport.
|
Raise opener rockshaft
to maximum height before transport.
|
| |
Seed treatment build-up on metering wheels.
|
Clean meter wheels.
|
| |
Drive chain misalignment.
|
Check chain alignment
and correct.
|
| |
Wet, swollen seed in meter.
|
Clean seed out of meter.
|
| |
Drive sprocket engagement off.
|
See Install Meter Door
Assembly in Operating Machine—Meters section.
|
| |
Transmission output and clutch shafts mis-aligned.
|
Align clutch shaft to
transmission output shaft.
|
| |
Shear couplers spread apart.
|
Shift clutch shaft toward
transmission to compress shear couplers together.
|