Determine Manifold Pressure
NOTE: Ambient air temperature and altitude can both effect air
flow. Adjust manifold pressure when these conditions affect performance.
Manifold pressure is correctly set when:
-
Equal amounts of product are delivered to each boot.
-
Tubes and hoses do not plug.
-
Hoses empty quickly and evenly when shut down.
-
Seed is not blowing out of seed trench.
| |
|
Manifold Pressure Settings
|
|
Pressure with 19 cm (7.5 in) Row Spacing
|
Pressure with 25 cm (10 in) Row Spacing
|
Pressure with 38 cm (15 in) Row Spacing
|
Used for
|
Notes
|
|
14" H2O
|
14" H2O
|
14" H2O
|
Sorghum
|
|
|
30" H2O
|
30" H2O
|
23" H2O
|
Wheat
|
Adjust pressure upward if plugging occurs. High seeding speeds
or high seeding rates require higher manifold pressure setting.
|
|
30" H2O
|
30" H2O
|
23" H2O
|
Soybeans
|
Adjust pressure upward if plugging occurs. High seeding speeds
or high seeding rates require higher manifold pressure setting.
|
|
30" H2O
|
30" H2O
|
|
Barley, Oats, Rice
|
Adjust pressure upward if plugging occurs. High seeding speeds
or high seeding rates require higher manifold pressure setting.
|
|
|
OUO6074,0000E0B-19-20160302
|
|