Convert From Narrow To Wide Row Spacing

IMPORTANT: Blockage pattern must be selected (even or odd rows) on monitor when converting row width.

Tool configuration must be changed (wide rows) on monitor when converting row width.

A47155
A47155-UN-13JUN05

Mechanical Lock-Up

A56438
A56438-UN-13JUN05

Hydraulic Lock Up Shown Open

A - Cap Screw

B - Hydraulic Lock Up Valve

Machines Without Hydraulic Lock Up: Fully raise all openers. Install cap screw (A) in each front rank to lock in raised position.

Machines With Hydraulic Lock Up: Fully raise all openers and close front rank hydraulic lock up valve (B).

A56439
A56439-UN-13JUN05

A56440
A56440-UN-13JUN05

A74883
A74883-UN-30MAR12

Gate Detail

A56441
A56441-UN-13JUN05

Open Flow Position

A56442
A56442-UN-13JUN05

Shut Off Position

A - Slot

B - Gate Open

C - Gate Closed

Insert solid end of shut off gate into slot (A) in splitters to block seed flow from front rank.

OUO6074,0000E28-19-20120330