Convert From Narrow To Wide Row Spacing
IMPORTANT: Blockage pattern must be selected (even or odd rows)
on monitor when converting row width. Tool configuration
must be changed (wide rows) on monitor when converting row width.

A47155-UN-13JUN05
Mechanical Lock-Up

A56438-UN-13JUN05
Hydraulic Lock Up Shown Open
A - Cap Screw
B - Hydraulic Lock Up Valve
Machines Without Hydraulic Lock Up: Fully raise all openers. Install cap screw (A) in each front rank
to lock in raised position.
Machines With Hydraulic Lock Up: Fully
raise all openers and close front rank hydraulic lock up valve (B).

A56439-UN-13JUN05

A56440-UN-13JUN05

A74883-UN-30MAR12
Gate Detail

A56441-UN-13JUN05
Open Flow Position

A56442-UN-13JUN05
Shut Off Position
A - Slot
B - Gate Open
C - Gate Closed
Insert solid end of shut off gate into slot (A) in splitters
to block seed flow from front rank.
|
|
OUO6074,0000E28-19-20120330
|
|