Blower Motor Hydraulic Requirements

IMPORTANT: Avoid blower motor damage. Ensure that tractor case-drain has less than 172 kPa (1.72 bar) (25 psi).

Case drain hose (A) must be attached to low-pressure drain connection before any other hose connection.

A85599
A85599-UN-11MAR15

Case Drain Connected First

A - Motor (Case) Drain Hose

The hydraulic blower motors are low flow, high-pressure motors. The motors are designed to operate on a closed-center hydraulic system. Connecting the blower motor to an open-center system is not recommended. See your John Deere™ Dealer for more information.


John Deere is a trademark of Deere & Company