Hydraulic Connections Recommendations (Dual Blower System)

A82587-UN-15MAY14
Float

A82662-UN-27MAY14
Extend

A82661-UN-27MAY14
Retract

A92503-UN-21SEP16
Model Year 2014 9R Tractor with High Flow Hydraulic
Shown
|
9R Tractors (—Model Year 2013)
|
9R Tractors (Model Year 2014 and Up)
|
|
High flow hydraulics uses two hydraulic pumps providing up to
295 L/min (78 gal/min) of hydraulic flow. SCVs I, II, and III are
powered by a pump providing 182 L/min (48 gal/min) of hydraulic flow.
SCVs IV and V are powered by a pump providing 114 L/min (30 gal/min)
of hydraulic flow.
Functions that require high flow with low pressure, like the
blower motors, are connected to SCVs III and IV. All functions requiring
high pressure with low flow, such as hydraulic cylinders are connected
to SCVs I and II. Connecting in this way helps the system run cooler
by not producing excessive heat.
|
High flow hydraulics uses two hydraulic pumps providing up to
435 L/min (115 gal/min) of hydraulic flow. SCVs I, II, and III are
powered by a pump providing 218 L/min (57.5 gal/min) of hydraulic
flow. SCVs IV and V are powered by a pump providing 218 L/min (57.5
gal/min) of hydraulic flow.
Functions that require high flow with low pressure, like the
blower motors, are connected to SCVs III and IV. All functions requiring
high pressure with low flow, such as hydraulic cylinders are connected
to SCVs I and II. Connecting in this way helps the system run cooler
by not producing excessive heat.
|
| |
If machine hydraulic hoses are not equipped with circuit
identification tags, a service kit containing all tags is available.
Tag service kit AA78772 is available from your John Deere dealer.
Extend and Retract symbols are on the selective control valve
(SCV) cover and hose connections.
Refer to the tractor operator's manual for specific hydraulic
operational details.
Avoid hydraulic hose failure due to physical damage,
kinks, age, and exposure. Inspect hoses regularly. Replace damaged
hoses.
Avoid motor seal damage. Connect the case drain hose
before any other hose. Connect the blower return hoses to a tractor
“extend” SCV. Move tractor SCV lever to float (not neutral) position
to shut off the blower.
When the 1910 Air Cart is equipped with dual blowers,
the 13.1 m (43 ft) 1895 is the only compatible seeding tool.
|
Hydraulic Connection Identification
|
|
SCV Port
|
SCV Circuit
|
SCV Color
|
SCV Symbol
|
Implement Function
|
SCV Flow1
|
SCV Time1
|
|
(A)
|
Case Drain
|
Yellow
|
“D”
|
Non-Pressurized Hydraulic Return—All Functions2
|
N/A3
|
N/A3
|
|
(B)
|
Brake
|
N/A3
|
N/A3
|
Cart Brakes (If Equipped)
|
N/A3
|
N/A3
|
|
(C)
|
I
|
Green
|
Extend
|
Seeding Tool
Rockshaft Opener Control
|
10 Maximum
|
Continuous “C”
|
|
(D)
|
Retract
|
|
(E)
|
II
|
Blue
|
Extend
|
Seeding Tool Wing Fold
|
Start at 5.
|
10 seconds or as required.
|
|
(F)
|
Retract
|
Seeding Tool Wing Unfold
|
|
(G)
|
III
|
Brown
|
Extend
|
Bottom Shoot Blower Hydraulic Return4
|
10 Maximum
Blower speed controlled by hydraulic flow control of tractor.
|
Continuous “C”
Blower speed controlled by hydraulic flow control of tractor.
|
|
(H)
|
Retract
|
Bottom Shoot Blower Engage
|
| |
Float
|
Bottom Shoot Blower Disengage
|
|
(I)
|
IV5
|
Black
|
Extend
|
Top Shoot Blower Hydraulic Return4
|
10 Maximum
Blower speed controlled by hydraulic flow control of tractor.
|
Continuous “C”
Blower speed controlled by hydraulic flow control of tractor.
|
|
(J)
|
Retract
|
Top Shoot Blower Engage
|
| |
Float
|
Top Shoot Blower Disengage
|
|
(K)
|
V
|
Purple
|
Extend
|
Not Used for this Application (Model Year 2014 and Up)
|
N/A3
|
N/A3
|
|
(L)
|
Float
|
|
Power Beyond Connection Identification
|
|
SCV Port
|
SCV Circuit
|
SCV Color
|
SCV Symbol
|
(P) 9R Tractors with High Flow Hydraulics
(—Model Year 2013)6
|
(Q) 9R Tractors with High Flow Hydraulics
(Model year 2014 and Up)6
|
Implement Function
|
SCV Flow1
|
SCV Time1
|
|
(M)
|
Pressure
|
Red
|
“P”
|
Bottom Pump
182 L/min
(48 gal/min)
|
Top Pump
218 L/min
(57.5 gal/min)
|
Cart Hydraulic Drives and Section Command
|
N/A3
|
N/A3
|
|
(N)
|
Return
|
Black
|
“R”
|
|
(O)
|
Load Sense
|
Orange
|
“LS”
|
|
1 Adjust
as necessary for proper response.
2 Case drain hose must be attached before any
other hose being connected.
3 N/A = Not Applicable
4 Move SCV lever to Float position to disengage
the blower.
5 13.1 m (43 ft) 1895 uses
top and bottom shoot blowers when air cart is equipped with dual blowers.
6 See diagram
on previous page for proper location of connections.
|
BB83525,000045D-19-20170502
|
|