Determine if blockage is in primary or secondary hose.
-
Raise tool completely and close lockup valve.
-
Primary Hose: Remove primary hose
from the affected tower.
-
Shake hose vigorously starting at the air cart until blockage
spills from end of hose.
-
Reconnect hose.
-
Continue seeding and observe affected row for product flow.
-
If no seed flow is observed, repeat procedure.
-
Secondary Hose: Remove secondary hose
from the affected opener.
-
Shake hose vigorously until blockage spills from the end of
the hose.
-
If blockage is not in the secondary hose or the opener, remove
the lid from the tower and clear header ring.
-
Reconnect the secondary hose and install the lid if necessary.
-
Continue seeding and observe affected row for product flow.
-
If no seed flow is observed, repeat procedure.