Adjusting Pump to Pump Number Setting
NOTE:
After determining desired gallons per acre, set BOTH pumps at the number setting required.
Example: 762 mm (30 in.) row spacing and 19.0 gallons per acre. Set BOTH pumps at 5.0.
1.
Install special tool (A) on to pump pin (B) aligning teeth of tool with teeth of scale ring (C).
2.
Loosen nut (D) and rotate scale ring with special tool until pointer (E) is pointing to number on gauge (F) that was selected from the rate chart. Torque nut to 25 N·m (184 lb-ft).
A-Special Tool
B-Pin
C-Scale Ring
D-Nut
E-Pointer
|