Vacuum Level, Baffle Position and Vacuum Meter Brush for Peanuts

EXAMPLE: If seeds per pound is 800. Referring to the chart, the vacuum level should be set at 11 in., when using the Large Edible Bean Disk for Runner Peanuts or 8 in. when using the Virginia Peanut Disk.

IMPORTANT: The 11 in. or 8 in. vacuum level above is an example on how to use the chart. Obtain size in seeds per pound. You must calculate the proper vacuum level for each peanut variety.

VACUUM METER BAFFLE

Move tab (A).

Peanuts, upper position (B).

VACUUM METER BRUSH

Use the short brush.

Talc Lubricant, 2 cups.

NOTE: If sweet corn double eliminator has been installed, loosen set screw in cam nut and rotate cam nut to move tip of eliminator AWAY from center of meter housing as far as possible.

H42254
H42255

Upper Baffle Position

H41715

Short Brush

GENOM,VMSC,AL -19-24FEB97-1/1