IMPORTANT:
The 11 in. vacuum level above is an example on how to use the chart. You must calculate the proper vacuum level for each corn variety.
VACUUM METER BAFFLE: Move tab (A).
For corn, use upper position (B).
Adjust double eliminator as follows:
The double eliminator should be positioned to cover from 1/4 to 1/2 of the vacuum hole. The tooth to the far right of the double eliminator (one under the adjusting screw) is used. Set the double eliminator to the 1/4 position for seeds between 900 and 2000 seeds per pound. Set the double eliminator to the 1/2 position for seeds between 2000 and 3200 seeds per pound.
|