Setting Selective Control Valve for VACUMETER™-Advantage Series Tractors

IMPORTANT: Vacuum System must be connected to a DELUXE 301 SERIES VALVE on tractor.

IMPORTANT: Planter flow control valve must be set wide open and must never be allowed to control vacuum level.

Set SCV control knob (A) to motor position (continuous detent). Flow control knob (B) will be used to control vacuum level, start with flow control low and work up. The flow control valve on the machine must be set to full open position.

SCV lever should be in forward position for running and "float" for off. The motor has an over-running check valve to protect seals if accidentally put in neutral.

H45397

SCV No. II Illustrated


A-SCV Control Knob
B-Flow control Knob

VACUMETER is a trademark of Deere & Company

OUO1074,0000157 -19-19MAR01-1/1