Row Units

Symptom Problem Solution

Row units on right-hand side of machine not planting.

Right-hand drive shaft cotter pin sheared.

Repair cause of pin shearing and replace cotter pin.

Row units on left-hand side of machine not planting.

Left-hand drive shaft cotter pin sheared.

Repair cause of pin shearing and replace cotter pin.

All row units not planting on machine.

Bolt in countershaft sprocket to seed transmission sheared.

Repair cause of pin shearing and replace cotter pin.

Closing wheels leave severe imprint in soil.

Too much spring force.

Adjust closing wheel spring.

Closing wheels not firming soil around seed.

Insufficient spring force.

Adjust closing wheel spring.

Closing wheel running on top of seed furrow.

Improper centering.

Realign.

Closing wheels not applying equal force

Closing wheel frame not level.

Relevel.

Gauge wheels will not turn.

Too tight against double-disk opener.

Add washer(s) to gauge wheel arm.

OUO1074,000017F -19-22MAR01-1/1