Auger flighting does not turn, or turns slow.
|
Low hydraulic oil level.
|
Check and fill reservoir.
|
|
|
Pressurized return line.
|
Reverse hose connections to tractor or move control lever in opposite direction.
|
|
|
Tractor control valve return line closed.
|
Cycle control lever in opposite direction momentarily to open.
|
|
|
Tractor flow control set too low.
|
Increase valve setting.
|
|
|
Tractor pressure too low.
|
Check and repair tractor hydraulic system. See your John Deere dealer.
|
|
|
Selector valve set for FAN.
|
Pull valve handle out for AUGER operations.
|
|
|
Motor-to-flighting coupler damaged.
|
Replace coupling hardware.
|
|
|
Damaged shaft seal.
|
See your John Deere dealer.
|
|
|
Faulty selector valve.
|
Repair or replace valve. See your John Deere dealer.
|
|
|
Faulty control valve.
|
Repair or replace valve. See your John Deere dealer.
|
|
|
Faulty auger motor.
|
Repair or replace motor. See your John Deere dealer.
|
|
Auger spout hose plugs during fill.
|
Hose is too long.
|
Shorten hose to desired length.
|