Troubleshooting Air System

Symptom Problem Solution

Plugged air hoses or manifolds.

Air volume too low.

Increase fan speed.

Ground speed too fast.

Reduce ground speed or meter rate.

Foreign material blocking air system.

Clean air system hoses and manifold openings.

Unbalanced air flow (Double-Shoot System).

Adjust damper position.

Secondary hoses routed flat or uphill.

Reroute hoses correctly.

Non-compatible fertilizers.

Do not mix Urea with Ammonium Nitrate fertilizer.

High humidity.

Use moisture resistant fertilizer or wait for drier conditions.

Leaking air manifold.

Inspect wedge seals for tight fit.

Caulk manifold pieces together.

AG,OUO6023,1198 -19-21JUL00-1/2


Symptom Problem Solution

Uneven product distribution between runs.

Air leak between manifold and meter.

Check manifold to meter seal.

Product level too low for accurate metering.

Do not run tank empty; refill sooner.

Air volume too low.

Increase fan speed.

Meter tuning rings not installed, or wrong number installed.

Install correct number of tuning rings for secondary header ports.

Blockage in air lines or manifolds.

Clean air system and manifold openings.

Improper assembly of header ring.

Reassemble correctly.

Manifold slide not fully positioned in top-shoot or bottom-shoot position

Check for foreign material in slide path, manifold passages, and slide openings.

Variation in secondary hose lengths or routings.

Trim hoses to uniform lengths and re-route correctly.

Unbalanced air flow (Double-Shoot System).

Adjust damper position.

Tank not pressurized.

Inspect lid seal for leaks.

Clean manifold screens.

Clean tank pressurization hoses.

Clean manifold end caps and/or air control valves

Plugged seed boots.

Backing or turning with seeding tool in ground.

Raise seeding tool before backing or turning.

Seed damage.

Air volume too high.

Reduce fan speed.

Old, dry seeds.

Use fresh seeds.

AG,OUO6023,1198 -19-21JUL00-2/2