Uneven/Inaccurate metering or product delivery.
|
Air leaking past lid seal.
|
Adjust lid closing down pressure.
Replace seal.
|
|
|
Product level too low for accurate metering.
|
Do not run tank empty; refill sooner.
|
|
|
In-tank pressure tubes (ladder rails), air control valves, or manifold end cap screens plugged.
|
Clean tubes, air valves, and screens.
|
|
|
Tank pressurization hoses plugged.
|
Clean hoses.
|
|
|
Half-width disconnect(s) closed or partially closed.
|
Completely open both disconnects.
|
|
|
Foreign material blocking product passages.
|
Remove blockage. Use screens when filling tanks.
|
|
|
Lumps in seed or fertilizer.
|
Use clean seed. Remove lumps from fertilizer. Use screens when filling tanks.
Reset agitator shaft action.
|
|
|
Meter segment rings not installed or wrong number installed.
|
Install correct number of fine tuning rings for secondary header ports.
|
|
|
Improper assembly of header ring or air system.
|
Reassemble correctly.
|
|
|
Slide or manifold bypass openings plugged.
|
Clean openings.
|
| Symptom |
Problem |
Solution |
|
No product delivery with clutches engaged.
|
Meter overload; drive pin sheared.
|
Replace sheared drive pin with 2.5 mm diameter cotter pin. See OPERATING MACHINE - PRODUCT METERING.
Engage meter only when fan is running to avoid overload.
|
|
|
Manifold slide in wrong position.
|
Position slide correctly.
|
|
|
Half-width disconnects closed, blocking product from meter.
|
Open half-width disconnects.
|
|
|
Large product bridging meter entry.
|
Install agitators above active runs to keep product free flowing.
|
| Symptom |
Problem |
Solution |
|
Delivery rate above or below expected rate.
|
Tank not pressurized.
|
Adjust lid closing down pressure.
Check and replace lid seal.
Clean in-tank pressure tubes (ladder tubes), air control valves, and manifold end cap screens.
Clean tank pressurization hoses.
|
|
|
No enclosure doors installed.
|
Install doors on inactive runs.
|
|
|
Incorrect transmission speed setting.
|
Review rate chart and reset transmission.
Perform monitor calibration.
Check tire speed sensor gap and calibration.
|
|
|
Wrong meter segments for product in use.
|
Replace meter segments with correct segments for desired application rate.
Check transmission settings.
Check monitor set-up and calibration.
|
|
|
Inaccurate rate check results.
|
Rerun rate check.
|
|
|
Plugged product passages or meter segment flutes.
|
Check and remove caked product from passages and segments.
|
|
|
Wrong drive sprockets installed.
|
Change sprockets to agree with rear tire size and tillage row spacing.
|
|
|
Transmission crank turned in wrong direction during calibration.
|
Rerun rate check, turning crank counterclockwise.
|
|
|
Slide or manifold bypass openings plugged.
|
Clean openings.
|
|
|
Manifold slide in wrong position.
|
Position slide correctly.
|
| Symptom |
Problem |
Solution |
|
|
Half-width disconnects not fully open.
|
Move handles down to open product passages. Rerun rate check.
|
|
|
Variable rate not established.
|
Build rate selection menus. Perform variable rate set-up.
|
|
Manifold slide difficult to reposition.
|
Desired rates exceed capacity.
|
Reduce speed or add more primaries.
|
|
|
Foreign objects in slide path
|
Inspect for and remove foreign objects.
|
|
|
Material collects on slide.
|
Tap lightly on slide handle. Remove slide and coat with a PTFE or graphite lubricant.
|