No population reading on display.
|
Meters/main drive not engaged.
|
Engage meters/main drive.
|
|
|
Seed counting controller not connected to harness.
|
Check sensor connections to controller and check harness connection to controller.
|
|
|
Slave jumper connector attached to both counting controllers.
|
Remove unnecessary slave jumper and replace with dust cap. Cycle power.
|
|
|
RUN page conflict.
|
Perform RUN page layout.
|
|
Seed counting population too "High".
|
Incorrect setup in Air Cart.
|
Press Setup/Air Cart/Seeding Tool/Air System to verify correct number of secondaries per primary and correct row spacing for each meter. Also check that each primary is set up with the correct tank feeding.
|
|
|
Incorrect meter setup.
|
Verify correct number of fine tuning rings on meter matches the number of rows in the Air Cart Setup.
|
|
"Primary not seeding" warning.
|
No product.
|
Tank empty, fill with seed.
|
|
|
Meter segment and/or product run blocked.
|
Clean out meter segment and/or unblock product run.
|
|
|
Half-width disconnect engaged.
|
Enable product flow by opening half-width disconnect lever.
|
|
Diagnostics on counting sensor.
|
Sensor dirty or damaged or controller damaged.
|
See Flow Chart 3.
|
| Symptom |
Problem |
Solution |
|
Seed counting population low.
|
Incorrect Setup in Air Cart for row spacing and number of secondaries.
|
Press Setup/Air Cart/Seeding Tool/Air System to verify correct number of secondaries per primary and correct row spacing for each meter. Also check that each primary is setup with the correct tanks feeding.
Verify correct number of fine tuning rings on meter matches the number of rows in the Air Cart Setup.
|
|
|
Obstruction in meter/tank preventing product flow.
|
Check product passages for obstructions.
|
|
|
Sensor dirty or damaged.
|
Verify sensor status-Info/Seed Counter/Diagnostics/Counter Status.
See Flow Chart 3.
|
|
Seed counting population low or high.
|
Ground speed reading incorrect.
|
Verify radar calibration done correctly if used. Otherwise verify tire calibration is done correctly.
|
|
|
Incorrect seed size entered for grains.
|
If seeding cereals or grains, correct seed size in seed counter setup.
|