Switching from 19 cm (7.5 in.) to 38 cm (15 in.) Row Spacing (1860 No-Till Air Drill Only)

IMPORTANT: Do not change seed tool configuration info on SEEDSTAR ™ control unless machine has seed counting.

If machine has seed counting, change row spacing configuration from 19 cm (7.5 in.) to 38 cm (15 in.) and change all inactive primaries on all tanks to "Not Feeding". See Air Cart Set-up Mode-Configure Seeding Tool and Air System.

1. Lift half-width disconnect handle (A) on air cart to shut off product flow to rank of openers that will not be used. See Operating Machine-Product Metering section.

A41852A


A-Half-Width Disconnect Handle

SEEDSTAR is a trademark of Deere & Company

OUO6076,00001C8 -19-03APR01-1/4


2. Hairpins (B) for agitators (A) on inactive runs must be removed to prevent damage to agitator shaft and crank. See Operating Machine-Product Metering section.

3. If equipped with blockage warning system, SEEDSTAR ™ setup will need to have sensors turned off for the inactive runs to prevent alarms. See Operating Machine-Monitor Operation section.

4. If equipped with seed counting, SEEDSTAR ™ setup will need to have seed counting turned off for the inactive runs to prevent alarms. See Operating Machine-Monitor Operation section.

A42568


A-Agitators
B-Hairpins

SEEDSTAR is a trademark of Deere & Company

OUO6076,00001C8 -19-03APR01-2/4


5. Raise all openers on tool fully, and close hydraulic valve to lock up rank of openers which will not be used for seeding. Close front rank valve (A) to lock up front rank of openers or close rear rank valve (B) to lock up rear rank of openers for 38 cm (15 in.) spacing.


A-Front Rank Valve
B-Rear Rank Valve

A47310

OUO6076,00001C8 -19-03APR01-3/4


NOTE: If equipped with dual implement switch option, cable connected to switch on rank of openers to be used for seeding must be connected to cart. Cables and switches are marked with color-coded tie bands for ease of identification.

6. If seeding tool is equipped with single remote switch (A) option, implement switch will need to be moved to the rank of openers that will be used for seeding.

7. If seeding tool is equipped with row markers, marker adjustment may be necessary to maintain proper row spacing.

IMPORTANT: If applying seed rates greater that 65 lb/acre on 38 cm (15 in.) spacing from a single tank, green meter rollers may need to be installed in air cart meters. See Operating Machine-Product Metering section.

8. Calibrate meters according to procedure specified in this manual. This will give correct transmission setting for desired seed rate.

(Approximately double the value listed in the rate charts listed this manual.)

A37887


A-Single Remote Switch