Determining Fan Speed

IMPORTANT: Do not exceed 5000 rpm maximum fan speed.

NOTE: Refer to SETTING FAN SPEED in Operating the Machine - Monitor Operation section.

Fan RPM setting will vary depending upon:

  • number of primary air runs
  • density and size of material
  • metering rate
  • ground speed

Fan speed is correctly set when:

  • equal amounts of product are delivered to each boot
  • tubes and hoses do not plug
  • hoses empty quickly and evenly when shut down

NOTE: Ambient air temperature and altitude can both affect air flow. Adjust fan speed when these conditions affect performance.

· Single-Shoot

Determine initial fan RPM setting by adding application rates of front and rear tank products together, for combined rate. Locate combined rate/fan RPM setting in chart.

Combined Rate Fan RPM
Light - 6-56 kg/hectare (5-50 lb/acre) 2200-2800 rpm
Medium - 56-112 kg/hectare (50-100 lb/acre) 2800-3500 rpm
Heavy - 112-224 kg/hectare (100-200 lb/acre) 3500-4200 rpm
Extra Heavy - 224-392 kg/hectare (200-350 lb/acre) 4200-5000 rpm

 

· Double-Shoot

IMPORTANT: Lower application rate product is usually placed in front tank.

Determine initial fan RPM setting based on the higher application rate product (rear tank).

AG,OUO6023,1070 -19-21JUL00-1/2


Higher Rate Product Fan RPM
Fine Products (i.e. Canola, Granular) 2500-3500 rpm
Coarse Grain 3500-4000 rpm
Fertilizer:
Light - 56-112 kg/hectare (50-100 lb/acre) 3300-4000 rpm
Medium - 112-224 kg/hectare (100-200 lb/acre) 4000-4700 rpm
Heavy - 224-392 kg/hectare (200-350 lb/acre) 4700-5000 rpm

 

NOTE: Double-Shoot damper is adjusted to divide and balance air flow between top and bottom runs.