All of the following items should have been entered during set-up mode procedures. The monitor and control system will not operate properly if an item was omitted or missed.
Initial Setup:
[ ] Adjust display contrast and backlight.
[ ] Refresh RUN pages using RUN Page Layout.
[ ] Configure Air Cart.
-
Enter zero for air sensors.
-
Enter tire sprocket tooth count.
-
Enter row spacing sprocket tooth count.
-
Enable Variable Rate (if equipped).
-
Enter cart size, i.e., 195, 270, or 350.
[ ] Configure Seeding Tool.
-
Enter seeding tool width.
-
Enter row spacing for EACH tank.
[ ] Configure Air System.
-
Select Single- or Double-Shoot air system.
-
Enter number of active primary lines, both top and bottom runs.
-
For each Primary:
-
Select "FEEDING" for each tank that will supply product to this primary.
-
Enter the number of secondary ports on the secondary manifold fed by this primary.
[ ] Calibrate Sensors.
-
Manually enter initial calibration value (mm/in. per rev.) for rear tires in use.
|
-
Perform final in-field calibration procedure.
[ ] Connect Tractor Radar (if equipped).
[ ] Connect Implement Switch (if equipped).
[ ] Refresh RUN pages using RUN Page Layout.
Options Setup:
[ ] Blockage System.
-
Setup Sensors; i.e., allow system to detect all sensors.
-
If Primary-Only system, select PRIMARY ONLY BLOCKAGE on PAGE 2.
-
Check that all sensors being used are turned "ON".
-
Header/Sensor configuration.
-
For Primary-Only blockage, verify that each Sensor is fed by the appropriate bank of primaries.
-
For All-Run blockage, verify that each Header is fed by the appropriate bank of primaries.
-
Set Reaction Level on PAGE 2.
[ ] Seed Counting System.
-
Enter number of sensors.
-
Check that all sensors being used are turned "ON".
-
Enter Seed Size for EACH tank.
-
Enter High Population Warning if value other than default value is desired.
-