Protecting Hydraulic Motor Seals-Low-Pressure (Case) Drain Connection
IMPORTANT:
Case drain hose (A) must be plugged into tractor OR placed in storage bracket (C) at ALL times to prevent damage to CCS fan motor seals.
IMPORTANT:
Fan motor case drain hose MUST be attached to low-pressure drain connection PRIOR to inlet and return hoses being connected. Case drain MUST have LESS THAN 172 kPa [1.72 bar] [25 psi] or fan motor will be damaged.
IMPORTANT:
Installation of a Low-Pressure Drain Line Kit is required if towing tractor is not so equipped.
IMPORTANT:
DO NOT USE other ports at the rear of the tractor (such as power-beyond ports) which may be similar in appearance and size to low-pressure drain port. Due to high back-pressure (over 172 kPa [1.72 bar] [25 psi]), drain connection to these ports WILL RESULT in fan motor damage.
Attach fan motor case drain hose (A) to tractor low-pressure drain coupler (B) or storage bracket at all times. If case drain hose is not attached at all times, pressure fluctuations from temperature changes will damage motor seals.
A-Case Drain Hose
B-Low-Pressure Drain Coupler
C-Storage Bracket
|