Liquid Fertilizer System

Symptom Problem Solution

Fertilizer flow rate slow or stopped.

Excessive drive tire slippage.

Unit Mounted Single-Disk Injection Opener Only: Excessive fertilizer manifold pressure due to too small nozzle or plugged nozzles.

Reduce row unit downforce, or check drive for misalignment or binding.

Plugged nozzle.

Unit Mounted Single-Disk Injection Opener Only: Clean nozzle.

Plugged strainer.

Clean strainer.

Kinked delivery hose at wings or at row.

Fix or replace hose.

Not enough pressure in distribution manifold (Injection Coulter).

Unit Mounted Single-Disk Injection Opener Only: Use smaller nozzle to raise manifold pressure. Add gauge to monitor pressure.

Drive tire or contact tire pressure low.

Inflate to proper pressure.

Fertilizer rate uneven row to row. (Unit Mounted Double-Disk Fert. Opener or Frame Mounted Single-Disk [Low Pressure/Flow Divider Delivery] Only)

Need 1 psi check valves for low rates with flow divider.

Install check valves.

Some fertilizer hoses may be pinched.

Find a fix hoses.

Fertilizer rate uneven row to row. (Unit Mounted Single-Disk Injection Opener [High Pressure/Manifold Delivery])

Not enough pressure in distribution manifold.

Use smaller nozzle to raise manifold pressure. Add gauge to monitor pressure.

Nozzle plugged.

Clean or replace.

Nozzles of mixed sizes used.

Use orifice or nozzle of same sizes.

AG,OUO6074,1695 -19-07AUG00-1/2


Symptom Problem Solution

Fertilizer opener does not penetrate sufficiently.

Improper adjustment of pressure.

Move bolt to lower position.

Fertilizer opener penetrates too deeply.

Improper adjustment of pressure.

Move bolt to upper position and adjust spring bolt.

One fertilizer opener not distributing fertilizer.

Check valve bad or installed in wrong direction.

Replace or reassemble check valve.

Fertilizer tube opener spout plugged.

Inspect, clean and remove obstruction.

Manifold pressure too low.

Use smaller nozzles to increase pressure to between 138 kPa (1.3 bar)(20 psi)-483 kPa (4.8 bar)(70 psi). Add gauge to monitor pressure.

Drive tire or contact tire pressure low.

Inflate to proper pressure.

Flow divider system hose pinched, preventing flow to opener.

Reroute hose.