IMPORTANT:
Do not use an open center tractor hydraulic system to operate machine. Permanent damage to tractor pump may result.
For complete tractor operating instructions, refer to the tractor operator's manual.
The CCS fan and VACUMETER™ pump hydraulic systems are designed to be operated with closed
|
center tractor hydraulic systems (tractors with load sensing or pressure on demand hydraulics are classified as closed center systems). Open center tractor hydraulics are NOT compatible with system.
Minimum tractor standby pressure required to operate the rephasing lift circuit, CCS fan and vacuum meter pump hydraulic systems are approximately 17,237 kPa (172 bar) (2500 psi) depending on frame configuration, planting speed and number of rows on machine.
|