PA (Population Adjust)

A49806
A49806-UN-08AUG02

A - SETUP SELECT Switch

PA (POPULATION ADJUST) is best used with high delivery rates or small seeds when the sensors are not able to count every seed.

PA (POPULATION ADJUST) This number represents a “correction factor” by which Population readings are multiplied, prior to being displayed. A “PA” number of 1.00 causes no change in the population readings. A “PA” number of 2.00 causes population numbers to double before being displayed.

NOTE: The minimum number allowed is 0.5 and the maximum number allowed is 2.50. Any number less than 0.5 or greater than 2.50 will not allow the SETUP function to be exited until a number within this range is entered.

Repeatedly press SETUP SELECT switch (A) until PA is displayed in left-hand column.

Use DIGIT SELECT and 0-9 switches to enter values.

Example:

If 100 000 seeds/acre is displayed on monitor but 150 000 are actually being planted, a PA value of 1.5 should be entered. This would cause the monitor to multiply each seed detected by 1.5 and increase the accuracy displayed.


COMPUTER TRAK is a trademark of Deere & Company

OUO6074,0000700-19-20050330