PA (Population Adjust)

A49806-UN-08AUG02
A - SETUP SELECT Switch
PA (POPULATION ADJUST) is best used with high delivery rates
or small seeds when the sensors are not able to count every seed.
PA (POPULATION ADJUST) This number represents a “correction
factor” by which Population readings are multiplied, prior to
being displayed. A “PA” number of 1.00 causes no change
in the population readings. A “PA” number of 2.00 causes
population numbers to double before being displayed.
NOTE: The minimum number allowed is 0.5 and the maximum number
allowed is 2.50. Any number less than 0.5 or greater than 2.50 will
not allow the SETUP function to be exited until a number within this
range is entered.
Repeatedly press SETUP SELECT switch (A) until PA is displayed
in left-hand column.
Use DIGIT SELECT and 0-9 switches to enter values.
Example:
If 100 000 seeds/acre is displayed on monitor but 150 000 are
actually being planted, a PA value of 1.5 should be entered. This
would cause the monitor to multiply each seed detected by 1.5 and
increase the accuracy displayed.
|
COMPUTER
TRAK is a trademark of Deere & Company
|
OUO6074,0000700-19-20050330
|
|