Edible Beans (Flat-Type Seed Disk)-30 in. to 40 in. Rows-Meter Setup and Rate Chart
Move vacuum meter baffle tab (A) to upper position (B).
Adjust double eliminator as follows:
Turn cam nut (C) to move top of double eliminator (D) toward center of housing as far as possible. Tighten screw (E).
Use regular (long) vacuum meter brush.
For talc application, see USE OF TALC LUBRICANT in Operating Vacuum Meter section.
For vacuum level, see VACUUM LEVEL SEED CHART-FLAT EDIBLE BEAN DISK in Operating Vacuum Meter section.
A-Tab
B-Upper Position
C-Cam Nut
D-Double Eliminator
E-Screw
|