Troubleshooting Product Metering System

Symptom Problem Solution

Uneven/Inaccurate metering or product delivery.

Product level too low for accurate metering.

Do not run tank empty; refill sooner.

Foreign material blocking product passages.

Remove blockage. Use screens when filling tanks.

Lumps in seed.

Use clean seed. Use screens when filling tanks.

Reset agitator shaft action.

Seed bridging in tank.

Add John Deere talc lubricant to seed tank.

Seed Treatment

Increase talc use, decrease seed treatment use.

No product delivery with drive wheel engaged.

Meter overload; drive pin sheared.

Replace sheared drive pin with 2.5 mm diameter cotter pin. See OPERATING MACHINE - PRODUCT METERING.

Engage meter only when fan is running to avoid overload.

Large product bridging meter entry.

Install agitators above active runs to keep product free flowing.

Chain slipping on product.

Check chains for proper tension and adjust idlers as needed.

Meter door not firmly against meter box.

Tighten nuts until meter door is firmly against meter box.

Meter drive sprockets not fully engaging.

Adjust agitator sprocket to fully contact meter sprocket.

OUO6030,00003E0 -19-30MAR04-1/2


Symptom Problem Solution

Delivery rate above or below expected rate.

Incorrect transmission speed setting.

Review rate chart and reset transmission.

Perform meter rate check.

Wrong meter wheels for product in use.

Replace meter wheels with correct segments for desired application rate.

Check transmission settings.

Inaccurate rate check results.

Rerun rate check.

Plugged product passages or meter segment flutes.

Check and remove caked product from passages and segments.

Excessive drive slippage.

Check drives for binding or misalignment.

Planting too fast for rough field conditions.

Reduce speed.

Incorrect drive tire pressure.

Inflate to proper pressure.

Meter drive sprockets not fully engaging.

Adjust agitator sprocket to fully contact meter sprocket.

OUO6030,00003E0 -19-30MAR04-2/2