CCS fan motor leaks.
|
Case drain line crimped, not connected to low pressure port, or connected to wrong port with high back-pressure.
|
Repair fan motor.
To avoid future failures, be sure to connect drain line to low-pressure (sump) return on tractor or place hose in storage position. Case drain must have less than 172 kPa (1.72 bar) (25 psi).
|
|
|
CCS fan motor seal leaking.
|
Replace seal. See your John Deere dealer.
|
|
|
Case drain line pulled out of coupler on tractor.
|
Check hose routing of hydraulic hoses across hitch. Ensure case drain is properly attached to tractor. Repair fan motor.
|
| Symptom |
Problem |
Solution |
|
CCS fan not turning.
|
Check valve installed backwards.
|
Switch check valve orientation.
|
|
|
SCV not in continuous detent position.
|
Place SCV in retract detent position.
|
|
|
Low hydraulic oil level.
|
Check and fill reservoir.
|
|
|
Tractor control valve return line not open.
|
Cycle control lever in opposite direction momentarily.
|
|
|
CCS fan motor seal leaking.
|
Replace seal. See your John Deere dealer.
|
|
|
Faulty CCS fan motor.
|
Repair or replace motor. See your John Deere dealer.
|
|
|
Faulty CCS flow control valve.
|
Repair or replace valve. See your John Deere dealer.
|
|
|
Row unit switch is depressed.
|
Lower machine to ground and adjust switch as needed.
|
|
|
Row unit switch faulty.
|
Replace switch.
|
|
|
Flow control valve incorrectly set.
|
Increase flow control setting.
|
|
|
Return hose not fully engaged in SCV outlet.
|
Check connections. Reverse hoses if necessary to prevent pull out.
|
|
|
If auxiliary hydraulics system provided, fan switch in the OFF position.
|
Turn fan switch to ON position.
|
|
|
|
Make sure purge switch is in PLANT.
|
|
CCS fan vibrates.
|
Dirty fan blades.
|
Clean fan.
|
|
|
Broken fan blades; fan out of balance.
|
Replace fan assembly.
|
|
CCS fan surges.
|
Flow control valve incorrectly set.
|
Adjust flow control valve or replace.
|
|
Premature CCS fan motor seal failure.
|
CCS case drain not connected to sump.
|
Connect case drain hose to sump. Case drain must have less than 172 kPa (1.72 bar) (25 psi).
|
| Symptom |
Problem |
Solution |
|
Tank pressure too low.
|
CCS pressure gauge was not zeroed.
|
Zero CCS pressure gauge.
|
|
|
CCS pressure gauge hose not connected or damaged.
|
Reconnect or replace hose.
|
|
|
Tractor flow control set too low.
|
Increase valve setting.
|
|
|
Faulty CCS control valve.
|
Repair or replace valve. See your John Deere dealer.
|
|
|
Machine flow control valve set incorrect.
|
Increase valve setting.
|
|
|
Tractor pressure too low.
|
Check and repair tractor hydraulic system. See your John Deere dealer.
|
|
|
CCS fan motor seal leaking.
|
Replace seal. See your John Deere dealer.
|
|
|
Faulty CCS fan motor.
|
Repair or replace motor. See your John Deere dealer.
|
|
|
CCS fan turning backward.
|
Check valve removed from return line. Check and correct hose connections to tractor.
|
|
|
Excessive air leakage from tank.
|
Install lids.
|
|
|
Pressure gauge broken.
|
Repair or replace gauge.
|
|
Pressure gauge does not zero.
|
Gauge not adjusted.
|
Zero gauge. See ZEROING PRESSURE GAUGE in Operating Machine-Air System section.
|
|
|
Gauge damaged.
|
Replace gauge.
|
|
|
Moisture in gauge.
|
Dry out gauge.
|
| Symptom |
Problem |
Solution |
|
CCS fan turning on and off while going though the field.
|
Frame height too high causing horn button on row unit to open and close.
|
Adjust frame height. See ADJUST FRAME HEIGHT in your Operator Manual.
|
|
|
Row unit fan switch misadjusted.
|
Adjust switch. See SETTING CCS ROW UNIT FAN SWITCH in Service-As Required section.
|
|
CCS Fan/Agitator will not engage when planter lowered.
|
Inspect F3 10 amp fuse in frame control harness.
|
Replace fuse.
|
|
|
Check pins 1 and 7 on tractor/planter 7 pin connector for 12 volts.
|
See your John Deere dealer.
|
|
|
Check CCS fan solenoid for magnetism.
|
See CHECKING SOLENOIDS in Service section.
|
|
|
Check CCS row unit switch (left center row unit on parallel arms).
|
Adjust switch. See SETTING CCS ROW UNIT FAN SWITCH in Service-As Required section.
|
|
|
Check K31 relay.
|
Replace as needed.
|