Row Units

Symptom Problem Solution

Row units on right-hand side of machine not planting.

Right-hand drive shaft cotter pin sheared.

Repair cause of pin shearing and replace cotter pin.

Half-Width Drive Disconnect is engaged.

Move switch to middle position.

Row units on left-hand side of machine not planting.

Left-hand drive shaft cotter pin(s) sheared.

Repair cause of pin shearing and replace cotter pin.

Half-Width Drive Disconnect is engaged.

Move switch to middle position.

Closing wheels leave severe imprint in soil.

Too much spring force.

Adjust closing wheel spring.

Closing wheels not firming soil around seed.

Insufficient spring force.

Adjust closing wheel spring.

Closing wheel running on top of seed furrow.

Improper centering.

Align.

Closing wheels not applying equal force.

Misaligned.

Realign.

Monitor will not count seeds.

Rain has washed mud into seed tubes.

Clean off mud with cleaning brush.

OUO6023,00013C3 -19-24MAR01-1/1