Unit Mounted Coulter
CAUTION:
Raise machine and install service locks.
CAUTION:
Coulter blades are very sharp. Use caution to avoid being cut.
IMPORTANT:
Bottom edge of coulter blade should be approximately 10 mm (3/8 in.) above bottom edge of seed openers in normal conditions. (Check this dimension with machine in planting position on any level surface.) This dimension will minimize the force required for penetration and help maintain a constant seed depth. In heavy straw, penetration and cutting action may be improved if bottom edge of coulter blade is positioned slightly below bottom edge of seed openers.
NOTE:
Do not operate coulter deeper than seed opener, as this can affect seed depth.
The unit mounted coulter can be used to assist the TRU-VEE
opener to penetrate tough soil conditions and to cut or displace residue commonly found in reduced tillage conditions.
The coulter blade penetration depth is controlled with the opener gauge wheels, weight adjustment and cap screw (A). As blade wear occurs, loosen cap screw (A), lower arm to next notch and tighten nut.