Timing and Enabling Pumps

A54239

Front Pump

A54240

Rear Pump

 

A-Keyway

 

IMPORTANT: Double pump systems must have keyways (A) timed 90 degrees to each other when pump chains are reinstalled or machine damage will result.

If chains have been removed from pumps, turn pump drive sprockets by hand until keyway (A) on front pump and rear pump are 90 degrees offset from one another.

OUO6074,0000C98 -19-18MAY04-1/1