Split Row Configuration
Allows setting up row pattern for all rows on, even rows only, or odd rows only.
1.
Press SETUP (A) until PATRN display is shown.
2.
Enter desired pattern according to table shown, using SELECT (B) and SET (C). (See ENTERING MONITOR VALUES in this section.)
NOTE:
When a row pattern is selected, all rows are automatically turned ON or OFF according to the pattern. Individual rows can still be edited in row configuration screen, but only after a pattern is selected.
Split Row Pattern |
Population |
Blockage Row ON/OFF |
00 |
Divided by 2 |
All Rows On (Double Rank Only) |
01 |
Actual Population |
Odd Rows On |
02 |
Actual Population |
Even Rows On |
03 |
Actual Population |
All Rows On (Single Rank Only) |
NOTE:
When 01 or 02 is selected, the furthest left row is row 1 (when standing behind the machine). Due to various tool sizes, row 1 may be on the front or rear rank of machine.
|