How To Change Meter Rollers

IMPORTANT: Avoid meter binding. When the black meter rollers and small seed wear plates are used and small seed sizes approach 6 mm (0.25 in.), switch to standard wear plates or green meter rollers.

NOTE: Field peas and chick peas sometimes jam between the meter housing and the fine tuning rings. When this happens, the meter is very hard to turn. Remove the fine tuning rings and recalibrate. When fine tuning rings are removed, the rate charts and the standard calibration values no longer apply.

NOTE: The Very High Rate Meter is able to deliver enough product to overload the product tubes. Use the monitor calculation function to ensure the application rate does not exceed 13.6 kg/min (30 lb/min).

NOTE: When metering high rates through a seeding tool with 3 or 4 secondary manifolds, either install additional secondary manifolds or reduce ground speed.

Four types of fluted meter rollers accommodate a variety of different products, product delivery needs, and application rates. The rollers are color-coded for easy identification.

· Yellow (A) - Low Rates and granular products: Use with low rate products such as flax, canola, and alfalfa.

NOTE: When using the black meter roller and small seed wear plate. The maximum application rate will be reduced by approximately 30%. Using standard wear plates or a green fluted meter rollers may be necessary.

· Black (B) - Regular Rates: Use with seeds up to 6 mm (0.25 in.) diameter. This roller is most commonly used with wheat, barley, and small soybeans.

A49163


A-Low Rate Meter Roller
B-Regular Rate Meter Roller
C-High Rate Meter Roller
D-Very High Rate Meter Roller

OUO6076,0000203 -19-08JUN07-1/7


· Green (C) - High Volume Rates: Use with seeds (soybeans) larger than 6 mm (0.25 in.) diameter and with high rates of fertilizer.

· Blue (D) - Very High Rates: Use with very large seeds and with high rates of fertilizer up to 290 kg/ha (260 lb/ac).

To change rollers and application rate, perform the following.

OUO6076,0000203 -19-08JUN07-2/7


A60041
A60042


A-Cap Screw
B-Sensor Ring
C-Handle
D-End Cap
E-Flange Nuts
F-Seal
G-Enclosure
H-Meter Roller

1. Remove meter cartridge assembly from housing.

2. Remove cap screw (A), lock nut, spacer, sensor ring (B), and washers.

NOTE: Handle (C) must be installed in original position during reassembly.

3. Mark handle (C) position on end cap (D). Mark end cap orientation on cartridge assembly.

4. Remove flange nuts (E) and handle.

5. Remove end cap and seal (F).

NOTE: Each meter segment consists of an enclosure, meter roller assembly, wear plate, and brush. Do not mix segment components.

6. Number every enclosure (G) and divider in order. Components must be returned to original locations when procedure is complete.

7. Remove enclosure (G).

NOTE: If tuning rings or meter rollers are reinstalled in a different order, product may not be delivered to distribution towers properly.

8. Note number of tuning rings on meter roller (H) before removing roller. Keep roller components and corresponding enclosure together. Do not mix segment components.

A60043
A60044

OUO6076,0000203 -19-08JUN07-3/7


9. Remove meter roller (A) assembly from shaft.

10. Locate beveled edge (B) on roller.

11. Remove snap ring (C) and bearing plate (D) from same side as beveled edge.

12. Remove meter roller. Note number of tuning rings. Install same number of tuning rings on replacement meter roller (see CUSTOMIZE METER SEGMENTS in this section). Assemble replacement meter roller, bearing plate, and snap ring.


A-Meter Roller
B-Beveled Edge
C-Snap Ring
D-Bearing Plate

A60053
A60055
A60054

OUO6076,0000203 -19-08JUN07-4/7


A60056
A60057
 

A-Standard Wear Plate

B-Small Seed Wear Plate (Yellow)

 

NOTE: When using the black meter roller and small seed wear plate. The maximum application rate will be reduced by approximately 30%. Using standard wear plates or a green fluted meter rollers may be necessary.

13. Install proper wear plate.

  • Use small seed wear plate (B) with yellow meter roller or with black meter roller when seeding cereal grains.
  • Use standard wear plate (A) with green or blue meter roller.

14. Keep enclosure and meter roller together. Remove next enclosure and repeat procedure. Continue until all meter rollers are replaced. Do not install meter rollers or wear strips of different colors in meter cartridge.

NOTE: Use aligning pegs and holes to aid enclosure installation onto meter cartridge.

15. Install meter rollers and corresponding enclosures onto meter cartridge in the order noted earlier.

OUO6076,0000203 -19-08JUN07-5/7


A60041
A60042


A-Cap Screw
B-Sensor Ring


C-Handle
D-End Cap


E-Flange Nuts


F-Seal

16. Install previously removed end cap (D) and seal (F) in original position as previously marked.

17. Install previously removed meter handle (C) in original position as previously marked.

IMPORTANT: Do not over tighten flange nuts (E). Overtightening distorts plastic enclosures and restricts meter rotation. Overtightening also increases wear on meter components and causes rod to interfere with sensor ring.

18. Tighten flange nuts (E) until one or two threads are visible past top of flange nut.

NOTE: Fully assembled meter cartridge rotates easily by hand.

19. Install previously removed washers and sensor ring (B).

20. Install previously removed cap screw (A), spacer and lock nut.

21. Install meter cartridge in cart.

OUO6076,0000203 -19-08JUN07-6/7


A50562

Meter Cartridge Assembly


A-Flange Nuts
B-Handle
C-Lock Nut
D-Sensor Ring
E-Cap Screw, M8 X 55
F-Spacer
G-Washers
H-Seals (End Cap)
I-Meter Shaft
J-End Cap
K-Meter Enclosure (4 used)
L-Meter Spacer


M-Meter Enclosure (4 used)
N-Meter Brush
O-Meter Door
P-Wear Plate
Q-End Cap
R-Washers (2 used)
S-Spring Pin, 5 X 20 mm
T-Seals (End Cap)
U-Meter Drive
V-Spring Pin, 8 X 35 mm
W-Meter Roller, Low Rate (Yellow)


X-Meter Roller, Regular Rate (Black)
Y-Meter Roller, High Rate (Green)
Z-Meter Roller, Very High Rate (Blue)
AA-Fine Tuning Rings, Low Rate (Yellow)
AB-Fine Tuning Rings, Regular Rate (Black)
AC-Fine Tuning Rings, High Rate (Green)


AD-Fine Tuning Rings, Very High Rate (Blue)
AE-Bearing Plate (2 used per Segment)
AF-Snap Rings (2 used per Segment)
AG-Tuning Ring Tool
AH-Tie Rod (2 used)
AI-Meter Inserts (2 used per Segment)
AJ-Assembled Meter Roller

OUO6076,0000203 -19-08JUN07-7/7