Liquid Fertilizer Sensor Calibration (Optional)
1.
Select
Menu
>>
Planter
button >>
Configuration
softkey >>
Sensor
tab.
2.
Select
Fertilizer
from drop down box.
3.
Select each sensor, one at a time, from the
Sensor
drop down box.
4.
Select
Cal Value
input box and enter the pressure per volt from the fertilizer sensor. John Deere
planters with factory equipped sensors have a calibration value of 37.50.
NOTE:
Some pressure remains trapped in the system even after it is shut down, unless manually relieved.
NOTE:
Current pressure is displayed on bottom left of screen.
5.
Relieve fertilizer pressure from system and select the
Zero Sensor
button.