Touchscreen Calibration

1. Select Menu >> Display button >> Diagnostic softkey.

2. Select Tests tab.

3. Select Color Test button. Three distinct colors appear for five seconds. If three colors do not appear, contact your John Deere™ dealer.

4. Select Touchscreen Test and touch the screen in area of suspected malfunction. A target image appears under tip of finger. If target image does not appear when screen is touched, contact a John Deere™ dealer.

5. Select Touchscreen Calibration button.

6. Touch the screen over each X symbol as it appears on screen. Several X symbols appear in sequence, then a screen appears to indicate if calibration is successful or unsuccessful.

Screen Area Information

Display Display Display Diagnostics Display Diagnostics Tests Tests Color Test Color Test Touchscreen Test Touchscreen Test Touchscreen Calibration Touchscreen Calibration Calibration Successful Calibration Successful Calibration Unsuccessful Calibration Unsuccessful Reset Touchscreen Calibration Reset Touchscreen Calibration
A59565

Display Button

A59567

Diagnostic Softkey

OUO6074,0000FC9 -19-02APR07-1/1