CCS Fan Assembly

Symptom Problem Solution

CCS fan motor leaks.

Case drain line crimped, not connected to low pressure port, or connected to wrong port with high back-pressure.

Repair fan motor.

To avoid future failures, be sure to connect drain line to low-pressure (sump) return on tractor or place hose in storage position. Case drain must have less than 172 kPa (1.72 bar) (25 psi).

CCS fan motor seal leaking.

Replace seal. See your John Deere dealer.

Case drain line pulled out of coupler on tractor.

Check hose routing of hydraulic hoses across hitch. Ensure case drain is properly attached to tractor. Repair fan motor.

AG,OUO6023,1197 -19-21MAR06-1/4


Symptom Problem Solution

CCS fan not turning.

Check valve installed backwards.

Switch check valve orientation.

Rockshafts are up.

Lower rockshafts.

Fold switch on rockshaft malfunctioning.

Check for continuity with leads down.

SCV not in continuous detent position.

Place SCV in retract detent position.

Low hydraulic oil level.

Check and fill reservoir.

Tractor control valve return line not open.

Cycle control lever in opposite direction momentarily.

CCS fan motor seal leaking.

Replace seal. See your John Deere dealer.

Faulty CCS fan motor.

Repair or replace motor. See your John Deere dealer.

Faulty CCS flow control valve.

Repair or replace valve. See your John Deere dealer.

Row unit switch is depressed.

Lower machine to ground and adjust switch as needed.

Row unit switch faulty.

Replace switch.

Flow control valve incorrectly set.

Increase flow control setting.

Return hose not fully engaged in SCV outlet.

Check connections. Reverse hoses if necessary to prevent pull out.

CCS fan vibrates.

Dirty fan blades.

Clean fan.

Broken fan blades; fan out of balance.

Replace fan assembly.

CCS fan surges.

Flow control valve incorrectly set.

Adjust flow control valve or replace.

Premature CCS fan motor seal failure.

CCS case drain not connected to sump.

Connect case drain hose to sump. Case drain must have less than 172 kPa (1.72 bar) (25 psi).

AG,OUO6023,1197 -19-21MAR06-2/4


Symptom Problem Solution

Tank pressure too low.

CCS pressure gauge was not zeroed.

Zero CCS pressure gauge.

CCS pressure gauge not connected or damaged.

Connect or replace hose.

Tractor flow control set too low.

Increase valve setting.

Faulty CCS control valve.

Repair or replace valve. See your John Deere dealer.

Machine flow control valve set incorrect.

Increase valve setting.

Tractor pressure too low.

Check and repair tractor hydraulic system. See your John Deere dealer.

CCS fan motor seal leaking.

Replace seal. See your John Deere dealer.

Faulty CCS fan motor.

Repair or replace motor. See your John Deere dealer.

CCS fan turning backward.

Check valve removed from return line. Check and correct hose connections to tractor.

Excessive air leakage from tank.

Install lids.

Pressure gauge broken.

Repair or replace gauge.

Pressure gauge does not zero.

Gauge not adjusted.

Zero gauge. See ZEROING CCS FAN PRESSURE GAUGE in Central Commodity System section.

Gauge damaged.

Replace gauge.

Moisture in gauge.

Dry out gauge.

Suction hose plugged.

Clean or replace hose as needed.

AG,OUO6023,1197 -19-21MAR06-3/4


Symptom Problem Solution

CCS fan turning on and off while going through field.

Frame height too high causing row unit switch to open and close.

Adjust frame height. See ADJUSTING FRAME HEIGHT in Preparing Machine section.

CCS on/off push button switch out of adjustment.

Adjust row unit switch. See SETTING CCS ROW UNIT FAN SWITCH in Service-As Required section.

CCS Fan/Agitator will not engage when planter lowered.

Inspect F3 10 amp fuse in frame control harness.

Replace fuse.

Check pins 1 and 7 on tractor/planter 7 pin connector for 12 volts.

See your John Deere dealer.

Check CCS fan solenoid for magnetism.

See CHECKING SOLENOIDS in Service section.

Check CCS row unit push button switch (left center row unit on parallel arms).

Adjust switch. See SETTING CCS ROW UNIT FAN SWITCH in Service-As Required section.

Roller switch on right rockshaft closed/improperly adjusted.

Adjust switch. See SETTING ROLLER ROCKSHAFT SWITCH in Service-As Required section.

Check K31 relay.

Replace as needed.

AG,OUO6023,1197 -19-21MAR06-4/4