Row Units

Symptom Problem Solution

Row units on right-hand side of machine not planting.

Right-hand drive shaft cotter pin sheared.

Repair cause of pin shearing and replace cotter pin.

Half-Width Drive Disconnect is engaged.

Move switch to middle position.

Row units on left-hand side of machine not planting.

Left-hand drive shaft cotter pins sheared.

Repair cause of pin shearing and replace cotter pin.

Half-Width Drive Disconnect is engaged.

Move switch to middle position.

Closing wheels leave severe imprint in soil.

Too much spring force.

Reduce closing wheel downforce.

Closing wheels not firming soil around seed.

Insufficient spring force.

Increase closing wheel downforce.

Closing wheel running on top of seed furrow.

Improper centering.

Align.

Closing wheels not applying equal force.

Misaligned.

Realign.

Monitor does not count seeds.

Dirt or debris has collected in seed tube or on sensor.

Clean seed tube and sensor with cleaning brush.

OUO6023,00013C3 -19-04JUN08-1/1