Setting Mechanical Selective Control Valve for VACUMETER-7810, 7720 and 7820 Tractors
IMPORTANT:
If vacuum level cannot be fine tuned adequately with the 200 Series tractor SCV, the planter flow control valve can be used to adjust vacuum. The tractor flow control valve must be fully open when using planter control valve.
SCV lever must be in forward position for running vacuum and variable rate drive and be moved to "float" position to deactivate. The motor has an over-running check valve to protect seals when accidentally put in neutral.
| FUNCTION |
KNOB (A) |
KNOB (B) |
| Machine Raise-Lower-Fold-CCS |
Detent |
SCV set Fast (Rabbit) CCS level controlled with CCS valve. |
| Independent Markers-Drawbar |
Detent |
Start in middle and Adjust |
| Independent Markers |
Detent |
Middle |
| Vacuum Motors (Connected to Separate SCVs and Controlled with Cab Functions) |
Continuous |
Start Low and Adjust |
| Vacuum Motors (Connected to One SCV or Power Beyond and Controlled with In Line Valve) |
Continuous |
Fast (Rabbit) |
| Variable Rate Drive |
Continuous |
Fast (Rabbit) |
|
Viewed From Cab
A-SCV Control Knob
B-Flow control Knob
|