IMPORTANT:
Double pump systems must have keyways (A) timed 90 degrees to each other when pump chains are reinstalled or machine damage will result.
|
If chains have been removed from pumps, turn pump drive sprockets by hand until keyway (A) on front pump and rear pump are 90 degrees offset from one another.
|