John Blue™ Fixed Rate-Adjusting Pump Setting Number
NOTE:
If equipped with Variable Rate Fertilizer, see your SeedStar™ 2 Monitor Operator's Manual.
1.
Use rate chart to determine PUMP SETTING number for desired application rate.
2.
Install adjustment tool (A) on pump pin (B) aligning teeth with scale ring (C).
3.
Loosen nut (D) and rotate scale ring until pointer (E) is aligned with pump setting number on gauge (F). Tighten nut to specification.
Specification
|
Nut
-Torque
|
25 N·m
|
(18 lb-ft)
|
|
A-Adjustment Tool
B-Pin
C-Scale Ring
D-Nut
E-Pointer
F-Gauge
|