John Blue™ Fixed Rate-Adjusting Pump Setting Number

NOTE: If equipped with Variable Rate Fertilizer, see your SeedStar™ 2 Monitor Operator's Manual.

1. Use rate chart to determine PUMP SETTING number for desired application rate.

2. Install adjustment tool (A) on pump pin (B) aligning teeth with scale ring (C).

3. Loosen nut (D) and rotate scale ring until pointer (E) is aligned with pump setting number on gauge (F). Tighten nut to specification.

Specification

Nut -Torque 25 N·m (18 lb-ft)

A35432


A-Adjustment Tool
B-Pin
C-Scale Ring
D-Nut
E-Pointer
F-Gauge

OUO6074,0000E74 -19-30JUN08-1/2


4. Store adjustment tool (A) on pin (B) located on pump mounting bracket. Attach tool with clip pin (C).


A-Adjustment Tool
B-Pin
C-Clip Pin

A47955

OUO6074,0000E74 -19-30JUN08-2/2