Demco™ Fixed Rate-Adjusting Pump Setting Number

1. Loosen bolts (A), using wrench (B).

2. Insert one tab on wrench (B) into hole (C).

3. Insert one tab of second wrench into hole (D).

4. Turn adjustment disk (E) clockwise to desired setting, using second wrench.

5. Tighten bolts (A).


A-Bolts (2 used)
B-Wrench
C-Hole
D-Hole
E-Adjustment Disk

A53333
A53134
A53135
A53136

OUO6074,0000E77 -19-02OCT06-1/1