Seed Calibration
1.
Select
Menu
button >> select
Drill Application
icon >> select
Function Toggle
until icon set 2 is displayed >> select
Seed Records
icon.
NOTE:
The seed record page is different with each hopper configuration. With a left-right tank configuration, the hoppers share one record page. Other configurations have separate seed record pages per hopper. Select
Next Page
and
Previous Page
to move between hoppers and records.
2.
Multiple application records can be stored. A record with a light-colored tab (A) is currently viewed. Select
Next Record
and
Previous Record
icons to view records with dark-colored tabs (B). The tab with a flashing number is the active record currently controlling the meter.
3.
Select drop-down menu (C) and choose a seed.
4.
Either Normal Seed or Fine Seed appears in location (D). Set butterfly valve and changeover switch, on the fan housing, to "N" for normal seed or "F" for fine seed.
5.
Select drop-down box (E) and enter desired rate of seed delivery in units displayed next to box.
6.
Select drop-down box (F) and enter target travel speed in units displayed next to box.
7.
Select drop-down box (G) and enter fraction of area to simulate for calibration. Do not exceed 1/10. The larger the area simulated the more accurate the calibration, but the sample is larger and can take longer to collect.
8.
Indicator (H) displays an "X" until calibration is completed properly. A checkmark appears after a successful calibration and calibration test.
9.
Set the meter gear according to the meter recommendation (I). Red indicates to disengage micrometer. Green indicates to engage micrometer.
|
Seed Records
Previous Record
Next Record
Left-Right Configuration Shown
A-Light Tab, View Record
B-Dark Tab, Hidden Record
C-Seed Selection Drop-Down
D-Seed Type, Normal or Fine
E-Desired Rate
F-Target Travel Speed
G-Right Indicator
H-Calibration Result
I-Meter Gear Recommendation
J-Meter Value Recommendation
|