Radar Calibration
IMPORTANT:
Perform calibration in the field under seeding conditions. Inflate all tires to specifications given in operator's manuals. Do not inflate to level given on tire sidewall.
Accurate system performance is dependant upon accurate radar calibration.
Some radars are integrated into tractor system. Calibrate these according to tractor operator's manual.
A radar that is connected directly to the GreenStar
™
harness is calibrated using the following procedure. Dickey John™ Radar is an example of a radar that is connected directly to the GreenStar™ harness.
1.
Select
Menu
>>
Performance Monitor
icon >>
Settings
icon.
2.
Select
Radar Connected To Display
check box and mark with a check.
3.
Select
Radar Calibration
icon.
4.
Follow the three step procedure listed on screen.
Step 1: Measure and mark a 122 m (400 ft.) course. Drive tractor approximately 3.2 km/h (2 mph) without pulling a load. Select
Radar Calibration
icon as front tires cross mark at one end of course.
Step 2: Maintain speed. Select
Radar Calibration
button as front tires cross mark at other end of course.
Step 3: Calibration is either successful or unsuccessful. Either a
Previous
button appears to repeat the procedure or an
Enter
icon appears to complete the procedure.
Radar connected to display
Radar connected to display
Calibrate Radar
Calibrate Radar
|