Operate the Drill with GreenStarâ„¢ Monitor System

The following operations are available through Icon Set One. Select Menu button >> select Drill Application icon >> select Function Toggle until icon set 1 is displayed.

Tramlines

During drill operation, tramlines adjust and operate automatically.

To manually adjust tramlines during operation, select Increase Tramline or Decrease Tramline . Indicated change displays in the top right corner of the drill application screen.

To cancel tramline adjustments and restore to initial setup, select Restore Tramline .

To disable tramlines, select Disable Tramline .

A63036

Increase Tramline

A63037

Decrease Tramline

A63038

Restore Tramline

A63035

Disable Tramline

NS43404,00000A2 -19-25NOV08-1/5


Seed Rate

During drill operation, seed rate can be adjusted from the drill application main screen.

To increase seed rate during operation, select Increase Seed Rate or Decrease Seed Rate icons. Seed rate adjustments are displayed above implement graphic on display.

To cancel seed rate adjustments and reset to pre-determined value, select Cancel Seed Rate .

To change the percent that seed rate adjusts with each selection of icon, perform the following:

1. Select Menu button >> select Drill Application button >> select Function Toggle icon to page 2 of function menu >> select Setup icon.

NOTE: A selection of 1-20% can be chosen.

2. Select rate increment input box (A) and select percentage rate of change.

A63039

Increase Seed Rate

A63040

Decrease Seed Rate

A63041

Cancel Seed Rate

A63046

Setup Icon

A63093


A-Input Box

NS43404,00000A2 -19-25NOV08-2/5


Seed Meter Shutoff

During operation, seed meters can be temporarily shut off.

Select Seed Meter Shutoff to disable meter. If equipped with 2 seed meters, seed meter shutoff shuts off left-hand meter only.

Select Right Meter Shutoff to disable right-hand seed meter. If equipped with one seed meter Right Meter Shutoff has no function.

A63031

Seed Meter Shutoff

A63032

Right Seed Meter Shutoff

NS43404,00000A2 -19-25NOV08-3/5


Markers

Marker switch turns marker function on and off. Engage marker switch and control markers with tractor selective control valve (SCV).

Obstruction feature is used to avoid damage from obstacles in the field. The following is an example if an obstacle is on the right-hand side:

1. Select Obstruction icon.
2. Raise right-hand marker.
3. Lower then raise left-hand marker.
4. Drive around obstacle.
5. Lower right-hand marker.
6. Select Obstruction icon again.

NOTE: Selecting Obstruction does not increase tramline settings or effect the tramline sequence.


A-Marker Switch

A63907

Marker Switch Shown in Off Position

A63033

Obstruction

NS43404,00000A2 -19-25NOV08-4/5


Manual Meter Start at Slow Speed

Select Manual Meter Start icon to start the meter when ground speed is below 5 km/h (3.1 mph). The meters operate at programed rate for 20 seconds or until ground speed reaches 5 km/h (3.1 mph), whichever occurs first. Product is over-applied until minimum speed is reached.

A63808

Manual Start

NS43404,00000A2 -19-25NOV08-5/5