Symptom |
Problem |
Solution |
|
Wheel sensor not sending any impulses, ring on display does not flash when in motion.
|
Adjust gap between wheel sensor and bar magnet to 3 mm (0.12 in.) maximum.
South pole of magnet must point to sensor. Check cable and 3-pin plug for damage, and replace if necessary.
Connect cable in controller correctly: brown=+12 volts; black=signal; blue=ground.
Sensor is defective. Replace it.
|
Area is not being recorded.
|
No input for "working width".
|
Key in a value for "working width".
|
|
Full-width shut-off is active.
|
|
Fan speed does not appear on display.
|
Fan sensor not sending any impulses.
|
Adjust gap between fan sensor and cam to 1.5 mm (0.06 in.) maximum. If sensor is defective, replace it.
Connect cable in controller correctly: brown=+12 volts; black=signal; blue=ground.
|
No acoustic warning when fan speed drops by more than 10%.
|
No value for nominal speed stored in memory.
|
Key in a value for nominal fan speed.
|
Seed meter drive alarm not triggered.
|
Sensor on sowing shaft not sending any impulses.
|
Adjust gap between sowing shaft sensor and magnet to 1.5 mm (0.06 in.) maximum. Check chain/drive shaft. If sensor is defective, replace it. Connect cable in controller correctly: green/yellow=signal.
|
|
Speed drops below minimum number of sowing shaft impulses.
|
If this occurs when sowing fine seed at low speed, increase ground speed. This is not a defect.
|