Rotate Seed Meters
Use this to verify drillshaft and meters turn without pulling machine through a field. Planter remains stationary during this test.
1.
Select
Menu
>>
Planter
button >>
Diagnostics
softkey >>
Tests
tab.
2.
Select
Rotate Meters
from drop down box.
3.
Select
Motor Selection
input box and select All or any single motor to rotate.
4.
The following must occur for this feature to function:
-
Planter must be unfolded.
-
Planter must be in raised position.
-
Planter must be stationary.
-
Variable rate hydraulics must be active.
Select
Meter Rotation
button. An audible tone sounds when meters stop turning. Each time the icon is pressed, the meters rotate approximately one half a revolution. If meters fail to move, a warning screen appears.
Rotate Seed Meter function can be accessed from the planter main Run page.
Screen Area Information
Planter Diagnostics
Planter Diagnostics
Tests
Tests
Rotate Meters
Rotate Meters
Motor Selection
Motor Selection
All
All
Ground Speed
Ground Speed
mph
Miles per hour
kph
Kilometers per hour
Wheel Sensor
Wheel Sensor
Active
Active
Inactive
Inactive
Planter Position
Planter Position
Up
Up
Down
Down
Motor
Motor
Target rpm
Target revolutions per minute
|